Heidenhain ND 1200R Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ausrüstung Heidenhain ND 1200R herunter. HEIDENHAIN ND 1200R User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - ND 1200R

Operating InstructionsND 1200RRadialSoftware Version2.8.xEnglish (en)6/2013

Seite 2

102.1 ND 1200R Shipment Contents ...

Seite 4

12 1 Operation1.1 ND 1200R Overview1.1 ND 1200R OverviewThe ND 1200R is an advanced digital readout (DRO) system for radial drilling machines using

Seite 5 - ND 1200R side panel

ND 1200R Radial 131.2 Basic Functions of the ND 1200R1.2 Basic Functions of the ND 1200RSwitching on the ND 1200RSwitch on the ND 1200R. The POWER s

Seite 6 - Symbols within notes

14 1 Operation1.2 Basic Functions of the ND 1200REstablishing a repeatable machine zeroIf your ND 1200R was configured to establish a machine zero upo

Seite 7 - Cleaning

ND 1200R Radial 151.2 Basic Functions of the ND 1200RPanel key descriptionsDescriptions of panel key functions are provided in the following pages for

Seite 8 - 8 Preface

16 1 Operation1.2 Basic Functions of the ND 1200RWIDE keys FunctionLeft frequently used function: Press the left WIDE key to initiate the function pro

Seite 9 - 1 Operation

ND 1200R Radial 171.2 Basic Functions of the ND 1200RLCD screen and soft key layoutND 1200R LCD screens display information in one of three operating

Seite 10

18 1 Operation1.2 Basic Functions of the ND 1200RDistance from target mode screen and soft keysThe Distance from target screen shows: List of targets

Seite 11 - Operation

ND 1200R Radial 191.2 Basic Functions of the ND 1200RND 1200R MenusPress the MENU soft key to display menu titles over the soft keys at the bottom of

Seite 13 - 1.2 Basic Functions of

20 1 Operation1.2 Basic Functions of the ND 1200RDATUM menu DATUM functionsPress the DATUM soft key to display soft key selections for zeroing, moving

Seite 14 - Switching off the ND 1200R

ND 1200R Radial 211.2 Basic Functions of the ND 1200RPATTERN menu PATTERN functionsPress the PATTERN soft key to select a drilling pattern. Soft keys

Seite 15 - Panel key descriptions

22 1 Operation1.2 Basic Functions of the ND 1200RSETUP menu SETUP functionsPress the SETUP menu soft key to display the collection of SETUP screens us

Seite 16

ND 1200R Radial 231.3 Preparing to drill1.3 Preparing to drillPower-up the ND 1200R Switch on the ND 1200R. The POWER switch is located on the rear

Seite 17

24 1 Operation1.3 Preparing to drillAdjust LCD screen contrastIf necessary, adjust the LCD screen contrast using the decimal point and +/- keys locate

Seite 18

ND 1200R Radial 251.3 Preparing to drillProbing a positionA position can be probed with a hard probe or a touch probe.To probe a point with a hard pro

Seite 19 - ND 1200R Menus

26 1 Operation1.3 Preparing to drillSelect a probe diameterA probe is required to zero the axes on a workpiece. The diameter of the probe can be adjus

Seite 20

ND 1200R Radial 271.3 Preparing to drillAligning the part to an axisAccurate drilling requires the part to be perfectly aligned along an axis. Misalig

Seite 21

28 1 Operation1.3 Preparing to drillAligning a pair of holes to an axisThere are certain times when the part needs to be aligned on the center of two

Seite 22

ND 1200R Radial 291.3 Preparing to drillEstablish a datumA datum can be created from a probed point, the center point of a probed hole or a point crea

Seite 23 - 1.3 Preparing to drill

ND 1200R Radial 3ND 1200R IntroductionND 1200R panel keysPanel keys are used to enter target position coordinates, send data via RS-232 and USB ports

Seite 24

30 1 Operation1.3 Preparing to drillMoving a datumIf the datum of the part is not reachable by a probe it can be moved by entering the coordinates fro

Seite 25

ND 1200R Radial 311.4 Targets1.4 TargetsEntering a targetThe ND 1200R allows simple entry of target position coordinates. As target position coordin

Seite 26

32 1 Operation1.4 TargetsOptional: Prior to pressing the FINISH key a drill diameter may be entered. The diameter is for user reference only and does

Seite 27

ND 1200R Radial 331.4 TargetsEntering an incremental target positionTo enter an incremental target position: Press the X axis key. Enter the X coord

Seite 28

34 1 Operation1.4 Targets Enter the Y coordinate for the new target relative to a previously entered target. Press the ABS/INC soft key to toggle to

Seite 29

ND 1200R Radial 351.4 TargetsEditing and clearing targetsEditing a targetTo edit a target: Use the UP and DOWN ARROW keys to select a target in the t

Seite 30

36 1 Operation1.4 TargetsMarking a targetPositions in the target list can be marked with a checkmark in order to identify the target for a future mach

Seite 31 - 1.4 Targets

ND 1200R Radial 371.5 Target patterns1.5 Target patternsTarget patterns allow a way to quickly create targets by entering parameters for target coor

Seite 32

38 1 Operation1.5 Target patternsFrame patternTo create a Frame pattern: Press MENU>PATTERN>FRAME. Use the UP and DOWN ARROW keys to navigate

Seite 33

ND 1200R Radial 391.5 Target patternsRectangle patternTo create a Rectangle pattern: Press MENU>PATTERN>RECT. Use the UP and DOWN ARROW keys t

Seite 34

4 PrefaceWide keys: Two programmable Wide keys are used to perform frequently used functions. These keys can easily be located by touch without taking

Seite 35

40 1 Operation1.5 Target patternsLine patternTo create a Line drill pattern: Press MENU>PATTERN>LINE. Use the UP and DOWN ARROW keys to naviga

Seite 36

ND 1200R Radial 411.5 Target patternsCircle patternTo create a Circle pattern: Press MENU>PATTERN>CIRCLE. Use the UP and DOWN ARROW keys to na

Seite 37 - 1.5 Target patterns

42 1 Operation1.6 Target programs1.6 Target programsTarget programs permit the user to save and run target list sequences for later use. This allows

Seite 38

ND 1200R Radial 431.6 Target programsRunning a programTo run a target program: Press MENU>PROG. Use the UP and DOWN ARROW keys to select a progra

Seite 39

44 1 Operation1.6 Target programsMirroring a programTo mirror a target program: Press MENU>PROG. Use the UP and DOWN ARROW keys to select a progr

Seite 40

ND 1200R Radial 451.6 Target programsDeleting a programTo delete a target program: Press MENU>PROG>. Use the UP and DOWN ARROW keys to select

Seite 41

46 1 Operation1.7 Navigating to a target1.7 Navigating to a targetThe ND 1200R displays all entered target positions as an R (radius) and A (angle)

Seite 42 - 1.6 Target programs

Installation, Setup and Specifications

Seite 43

48 2 Installation and Specifications2.1 ND 1200R Shipment Contents2.1 ND 1200R Shipment ContentsThe contents of your ND 1200R shipment are described b

Seite 44

ND 1200R Radial 492.1 ND 1200R Shipment ContentsRepackaging the ND 1200RWhen shipping the ND 1200R on to an end-user, repackage all ND 1200R component

Seite 45

ND 1200R Radial 5ND 1200R rear panelND 1200R side panel123546781 Power switch2 Power cord connector and fuse holder3 Power ground access4 HEIDENHAIN 1

Seite 46 - 1.7 Navigating to a target

50 2 Installation and Specifications2.2 Hardware Installation2.2 Hardware InstallationThe ND 1200R is easy to install. This section describes how to i

Seite 47 - Specifications

ND 1200R Radial 512.2 Hardware InstallationArm mounting (optional)Secure the arm mount adapter to the ND 1200R and bolt the adapter and ND 1200R to th

Seite 48

52 2 Installation and Specifications2.2 Hardware InstallationConnecting powerConnect the ND 1200R to power through a high-quality power surge suppress

Seite 49 - Repackaging the ND 1200R

ND 1200R Radial 532.2 Hardware InstallationConnecting encoders and probesAxis encoders and probes are attached to interface connectors on the rear of

Seite 50 - 2.2 Hardware Installation

54 2 Installation and Specifications2.2 Hardware InstallationConnecting a computerMeasurement result data can be sent to a computer over the RS-232 po

Seite 51

ND 1200R Radial 552.2 Hardware InstallationConnecting a headphoneAudio alerts can be sent to headphones in areas that are noisy and make it difficult

Seite 52

56 2 Installation and Specifications2.2 Hardware InstallationConnecting an optional foot switch or remote keypadThe optional foot switch and remote ke

Seite 53

ND 1200R Radial 572.3 Software setup2.3 Software setupThe operating parameters of the ND 1200R must be configured prior to using it for the first time

Seite 54

58 2 Installation and Specifications2.3 Software setupSetup menuMost operating parameters of the ND 1200R are configured using screens and data fields

Seite 55

ND 1200R Radial 592.3 Software setupSetup example: entering the supervisor passwordCritical setup parameters are password-protected. Only qualified pe

Seite 56

6 PrefaceInformation contained in this manualThis User's manual covers the operation, installation, setup and specifications of the ND 1200R. Ope

Seite 57 - 2.3 Software setup

60 2 Installation and Specifications2.3 Software setup Navigate from the menu to the Password setup field using the RIGHT ARROW key.  Enter the supe

Seite 58

ND 1200R Radial 612.3 Software setupOrder of setupThe ND 1200R setup software is contained on up to 12 screens, depending on the hardware configuratio

Seite 59

62 2 Installation and Specifications2.3 Software setupLanguage selection and product versionThe About screen contains selections for changing the lang

Seite 60

ND 1200R Radial 632.3 Software setupSupervisor passwordThe Supervisor screen contains the Password data field and Startup Zero choice field. Most set

Seite 61

64 2 Installation and Specifications2.3 Software setupTo enable Startup Zero: Highlight the Startup Zero choice field. Press the YES soft key. Pres

Seite 62

ND 1200R Radial 652.3 Software setupEncoder configurationThe Encoders and Misc screens contain data and choice fields for configuring the encoders.Enc

Seite 63

66 2 Installation and Specifications2.3 Software setup Highlight the Type choice field and then press a soft key to select the encoder type. Highlig

Seite 64

ND 1200R Radial 672.3 Software setup Highlight the Reversed choice field and then press the YES soft key to reverse the encoder count direction. Pre

Seite 65

68 2 Installation and Specifications2.3 Software setupMisc screenThe Misc screen encoder configuration fields include: Auto DRO counts: The number of

Seite 66

ND 1200R Radial 692.3 Software setupProbe configurationThe Radial screen contains data and choice fields for configuring a probe.Radial screenThe Radi

Seite 67

ND 1200R Radial 7Safety considerationsGeneral accepted safety precautions must be followed when operating the system. Failure to observe these precaut

Seite 68

70 2 Installation and Specifications2.3 Software setup Highlight the Side Oper choice field and then press a soft key to select side operation. High

Seite 69

ND 1200R Radial 712.3 Software setupError correctionThe ND 1200R provides Linear Error Correction for the R axis. LEC compensates for encoder and mach

Seite 70

72 2 Installation and Specifications2.3 Software setup Position the standard artifact along the R axis. Align the artifact as closely as possible to

Seite 71

ND 1200R Radial 732.3 Software setupTo perform the linear error correction in the LEC screen: Highlight the LEC menu item. Enter the Standard value

Seite 72

74 2 Installation and Specifications2.3 Software setupDisplay formattingThe Display screen contains data and choice fields for configuring display res

Seite 73

ND 1200R Radial 752.3 Software setup Highlight the MM Disp Res data field and enter the display resolution index number. For example, an index number

Seite 74

76 2 Installation and Specifications2.3 Software setupHot key assignmentsThe Hot Keys setup screen is used to map frequently used functions to front p

Seite 75

ND 1200R Radial 772.3 Software setupTo assign a function to a hot key: Press MENU>SETUP to display the setup menu and then highlight the Hot keys

Seite 76

78 2 Installation and Specifications2.3 Software setup Highlight the specific function and press the ENTER key to complete the assignment. In this ex

Seite 77

ND 1200R Radial 792.3 Software setupPrint formattingPrint formatting data and choice fields are contained in the Print screen.Print screenThe Print sc

Seite 78

8 Preface

Seite 79

80 2 Installation and Specifications2.3 Software setup Highlight the Print Axis Units choice field and press the YES or NO soft key to include or exc

Seite 80

ND 1200R Radial 812.3 Software setupPort configurationThe Ports screen contains data and choice fields for configuring communication parameters of the

Seite 81

82 2 Installation and Specifications2.3 Software setupTo configure ports: Press MENU>SETUP to display the setup menu and then highlight the Ports

Seite 82

ND 1200R Radial 832.3 Software setup Highlight the Parity choice field and press a soft key to select ODD, EVEN or NONE. Highlight the Data choice f

Seite 83

84 2 Installation and Specifications2.3 Software setup Highlight the EOC (end of character) Delay and EOL (end of line) Delay data fields and enter a

Seite 84

ND 1200R Radial 852.3 Software setupAudio volumeAn audible beep is emitted by the ND 1200R when a front panel key is pressed.Misc screenThe Misc scree

Seite 85

86 2 Installation and Specifications2.3 Software setupKey repeat rate adjustmentWhen a front panel key is pressed and held, the function repeats. The

Seite 86

ND 1200R Radial 872.3 Software setupScreen saver activationMisc screenThe Misc screen contains a data field for adjusting idle time required prior to

Seite 87

88 2 Installation and Specifications2.3 Software setupTime and date settingsClock screenThe Clock screen contains data fields for setting the time and

Seite 88

ND 1200R Radial 892.4 Specifications2.4 SpecificationsSpecificationsAxes 2 to 3 axesEncoder inputs  Linear and rotary encoders Analog 1 VPP TTLDisp

Seite 89 - 2.4 Specifications

ND 1200R Radial 91.1 ND 1200R Overview ...

Seite 90

90 2 Installation and Specifications2.4 SpecificationsDimensionsThe ND 1200R enclosure, tray stand and arm mount bracket dimensions are shown in the f

Seite 91

ND 1200R Radial 912.4 SpecificationsArm mount bracket

Seite 92

92 2 Installation and Specifications2.4 Specifications

Seite 93

IndexND 1200R Radial 93Aabs soft key ... 18absolute target, enter ... 31align, part ... 27arm mounting ... 51arrow keys ... 16Bbenchtop mounting ... 5

Seite 94

Index94 IndexPpanel keys ... 15part alignment ... 27align edge to axis ... 27align holes to axis ... 28password ... 59, 63patterncircle ... 41frame ..

Seite 95

IndexND 1200R Radial 95Uunit of measure ... 24usb printer, connecting ... 55Vvolume ... 85Wwide keys ... 16Xx/y soft key ... 17, 18Zzero soft key ...

Seite 96 - 96 Index

Index96 Index

Seite 98

1071586-20 · Ver00 · pdf · 6/2013

Kommentare zu diesen Handbüchern